During week 5, the scheduled time for spinning the solution and testing the second variable, angle, did not go as planned. The day of lab (May 1st, 2012), a Tuesday, was filled with scattered thunderstorms and rainfall. With the high temperature and precipitation, the humidity level rose very high and was quite different from the constant. The constant humidity from the first spinning session must be kept so there is a control n the experiment. The spinning will now occur in week 6, while the SEM imaging for the second set of samples dealing with angle changes will be viewed in week 7. Week 8 will be devoted to viewing the results and finding conclusions. The final report will be written in week 9 and week 10 will be the presentation.
The blog updates that we would like to include have to do with the following:
Other competition (companies that makes filters made from nanofibers)
Detailed explanation for filter design
Significance of results
Impact on society
Further changes that can be made if there was a re-experimentation
Saturday, May 5, 2012
Tuesday, May 1, 2012
Week 5 Cont. - SEM Details 1
![]() |
| Figure 17. Cressing Sputter Coater 208 HR[5] |
Monday, April 30, 2012
Week 5 Analyzing SEM Images
In week 4, the group began to research bacteria that could exist in water supplies and that would cause harm to the human body. Also in Week 4, the nanofibers were spun samples of PEO using different variable lengths that were stated was one of the parameters that would be altering. The spun PEO samples were at lengths 4, 6, 8, 10, 12, and 16 cm. These lengths are the distances between the syringe and the collecting plate . Altering these lengths changed the different diameters of the Electrospun fibers. The goal is to create a filter using these fibers and below is an analysis of the diameters of the fibers:
PEO - 4cm
| Figure 11. PEO Spun 4cm |
Figure 11 illustrates the diameters of the spun fibers at a distance of 4 cm from the needle and the collecting plate. This image is zoomed so that it would be easy to calculate the distance. Using ImageJ the group was able to estimate the distances of the threads. To take a proper estimate, the measurements were taken from 30 different threads. the average of the diameters were 67.17 nm. the standard deviation was 0.0175 μm.
PEO - 6cm
| Figure 12. Spun PEO 6cm |
In Figure 12 you see one nano fiber that was woven together through the electrospinning process. Using the Image J measuring tool that was used gave the results that the the fiber has diameter of 10 μm. This holds true to the research that was conducted earlier in the experiment. The diameters should increase to a certain point until they will decrease again. This comparison between 4 cm shows that the results are correct in creating new filtration technology. The measurements were taken from 30 fibers that are comming off of the long big fiber. the measurement average was. 161.49 nm. the standard deviation is 0.0801 μm.
PEO - 8cm
| Figure 13. Spun PEO 8 cm |
The SEM image at 8 cm also resulted in a picture of only one thread. The diameter in this thread was 7.485 μm which is a little bit finer than the thread spun at 6 cm. Although it is thinner than the thread from 6cm, the 8cm PEO thread is still thicker than the diameter of the thread spun at 4cm which was 0.5722 μm. As in the image before there was only one thread so there was no average taken and the final diameter at 8cm is 7.485 μm.
PEO - 10cm
| Figure 14. Spun PEO 10cm |
In Figure 14 the measurements were taken from 30 different fibers in the SEM image. This was just to get a better approximation of the diameters because there were more fibers spun in the 10cm sample than there was in the 4cm sample. The average of the diameters was 81.6 nm. The standard deviation 0.025 μm.
PEO - 12cm
| Figure 15. Spun PEO 12 cm |
The PEO results at 12 cm is the best just because of the quantity of the fibers that were spun and collected. Also the diameter is the smallest of all the fibers that were spun before. This image had lots of fibers and it was zoomed to 200nm. the average of 30 fibers is 49.52 nm. the standard deviation of the fiber diameters 14.39 nm
PEO - 16cm
| Figure 16. Spun PEO 16cm |
In Figure 16 you see that the fibers don't seem to be spun as well as the fibers before. The diameters are sill very small for the fibers but the fibers do not appear to be as stable. This sample was very running and did not have good results. The fiber diameters 120.56 nm and the standard deviation is 0.036 μm.
The ideal fiber seems to be the fiber spun at the distance of 12 cm. These fibers gave the smallest diameter which is what is needed when spinning fibers for a filter. With these current results it shows that the fiber chosen to spin would be a filter using a 12 cm distance, but there will also testing the angle of spin to get the ideal distance and angle for a fiber. When the angle results were acquired will be spinning an ideal filter out of the fibers. Currently the only realization is that one ideal variable which is 12 cm.
Saturday, April 28, 2012
Week 4 Cont. - Investigation of Filtration and Preventing Disease
The application of our nanofibers will be to create a filter that will block microbes and bacteria that cause disease. The conducted research in this specific area, more specifically, seeing what are the most common bacteria in contaminated water, what are the ranges of size of these bacteria, and the effects of the specific bacterium. The four most common bacteria in untreated water were Fecal Coliform (general), E. Coli, Enterococcus Faecium, and Giardia [14]. The overarching goal is to create a filter that has a specific pattern (most likely a square-crossing pattern) in order to block and trap the bacteria that are in the water supply. PEO is miscible in water that is why this experiment will a larger control in which other solutions that are immiscible in water can be spun and used.
Classification of Bacteria in Water that Cause Disease:
Fecal Coliform, as seen to the left, are rod-shaped, small, non-sporulating bacterium. They are not very hazardous to human health; however, specific strains of them (E. Coli) can be very dangerous and potentially life-threatening. Failing home septic systems can allow coliforms in the effluent to flow into the water table, aquifers, drainage ditches and nearby surface waters. Sewage connections that are connected to storm drain pipes can also allow human sewage into surface waters [14]. Animal waste as well as agriculture waste from fertilizers contribute to the formation of coliform. Severe diseases can arise from lethal strains of this bacterium such as: ear infections, dysentery, typhoid fever, viral and bacterial gastroenteritis, and hepatitis A [14]. Without proper treatment, deadly genetic mutations of the RNA inside the bacterium will be certain death. This specific bacterium is approximately 0.60~0.70 μm in diameter and has an approximate volume of 0.816 cubic μm. The nanofibers spun must be so the diameter of each fiber is approximately 0.50 μm and the area of the square pattern is smaller than the diameter of one of these bacteria.
A specific form of Fecal Coliform is E. Coli which is known to be a deadly without treatment. Virulent strains of E. coli can cause gastroenteritis, urinary tract infections, and neonatal meningitis.[14]. E. Coli is approximately 2.0 μm in length, has a diameter of 0.50 μm, and volume of 0.70 cubic μm. Although E. Coli is relatively easy to treat if found in the early stages of the disease, it can be lethal if found too late. E. Coli is especially tricky to diagnose because the symptoms arise right before serious illness so there is a insufficient amount of time to kill the bacterium.The image on the right shows how E. Coli are rod-shaped and also are always in colonies.
The last two common bacteria found in contaminated water are Enterococcus Faecium and Giardia. E. Faecium is quite large; with a length of 1 to 2 mm [14]. They can move very fast and are known to target human arteries and hearts. They usually overtake and replace Fecal Coliform in water supply by engulfing them through phagocytosis (cell membrane forming around a substance or foreign object) [14]. Giardia cysts are 8 to 14 μm and the actual bacterium is about 5 μm in diameter. Giardia has symptoms that mimic other gastrointestinal problems and the common symptoms are persistent diarrhea, weight loss, abdominal cramps, nausea, and dehydration. In general, the symptoms begin within a week after exposure and the acute symptoms can last for up to 2 weeks, but chronic symptoms can last for up to 2 months [14]. Usually it is not life-threatening but treatment must be given to get rid of both bacteria.
Since the smallest form of Fecal Coliform is the smallest parameter of bacteria size in water supply, a filter must be created to take the size and dimensions of the bacteria into account. The filter mechanism is actually possible to create because the size and pattern shape can be created through mechanical/technological systems.
Classification of Bacteria in Water that Cause Disease:
![]() | ||
| Figure 7. Fecal Coliform Colony (SEM magnified) [7] |
Fecal Coliform, as seen to the left, are rod-shaped, small, non-sporulating bacterium. They are not very hazardous to human health; however, specific strains of them (E. Coli) can be very dangerous and potentially life-threatening. Failing home septic systems can allow coliforms in the effluent to flow into the water table, aquifers, drainage ditches and nearby surface waters. Sewage connections that are connected to storm drain pipes can also allow human sewage into surface waters [14]. Animal waste as well as agriculture waste from fertilizers contribute to the formation of coliform. Severe diseases can arise from lethal strains of this bacterium such as: ear infections, dysentery, typhoid fever, viral and bacterial gastroenteritis, and hepatitis A [14]. Without proper treatment, deadly genetic mutations of the RNA inside the bacterium will be certain death. This specific bacterium is approximately 0.60~0.70 μm in diameter and has an approximate volume of 0.816 cubic μm. The nanofibers spun must be so the diameter of each fiber is approximately 0.50 μm and the area of the square pattern is smaller than the diameter of one of these bacteria.
![]() |
| Figure 8. E. Coli under SEM Imaging [10] |
The last two common bacteria found in contaminated water are Enterococcus Faecium and Giardia. E. Faecium is quite large; with a length of 1 to 2 mm [14]. They can move very fast and are known to target human arteries and hearts. They usually overtake and replace Fecal Coliform in water supply by engulfing them through phagocytosis (cell membrane forming around a substance or foreign object) [14]. Giardia cysts are 8 to 14 μm and the actual bacterium is about 5 μm in diameter. Giardia has symptoms that mimic other gastrointestinal problems and the common symptoms are persistent diarrhea, weight loss, abdominal cramps, nausea, and dehydration. In general, the symptoms begin within a week after exposure and the acute symptoms can last for up to 2 weeks, but chronic symptoms can last for up to 2 months [14]. Usually it is not life-threatening but treatment must be given to get rid of both bacteria.
![]() |
| Figure 9. E. Faecium infecting pulmonary tissue [10] |
![]() |
| Figure 10. Giardia in water supply [10] |
Since the smallest form of Fecal Coliform is the smallest parameter of bacteria size in water supply, a filter must be created to take the size and dimensions of the bacteria into account. The filter mechanism is actually possible to create because the size and pattern shape can be created through mechanical/technological systems.
Tuesday, April 24, 2012
Week 4 - SEM Imaging
The SEM produces 6 different signals which include: secondary electrons, back-scattered electrons (BSE), characteristic X-rays, light (cathodoluminescence), specimen current and transmitted electrons. The SEM that will be used, transmits secondary electron detector signals. There are 3 different types of microscopes that can be used which range from LM, TEM, SEM as shown in figure 5 [12].
| Figure 5. Functionality of LM, TEM, SEM [12] |
All three microscopes begin with the light source at the top illuminating to a condenser lens. During the next step the LM and TEM microscopes vary from the SEM because the specimen is between the first condenser lens and the objective lens. In the SEM microscope there is a second condenser lens for a better image. The LM microscope requires you to use your eye to look at the projection lens while the TEM uses a fluorescent screen [13]. The SEM makes a crisper image because it has the specimen after the objective lens, and instead the specimen then emits a signal to a signal detector which creates a crisp image as shown below.
| Figure 6. Difference between optical & SEM of a small marine organism [13] |
Sunday, April 22, 2012
Week 3 Cont. - Spinning Process *Detailed*
A major component that was not taken into account was the constants was the needle gauge. We chose a 21 gauge that had an inner diameter of 14.5 mm. The higher the gauge, the smaller the diameter becomes. It is important to keep the gauge constant because different sized gauges will change the diameter of respective nanofibers. This will cause innaccurate comparisons between the different spun fibers [11]. This was an important constant to add to the list because it is an important part of the apparatus. The rotational mixer used to mix the solutions was made by Elmeco Engineering Inc and the specific model was the Arma-Rotator A-1. When the spinning began some measurements were taken: the temperature was 24.3 degrees Celsius and the humidity was 26%.
Evan and Tristan began to spin the mixed solution that they created on the previous day. They started off by changing the distance variable and completed the first 6 deliverables. They spun at 4 cm, 6 cm, 8 cm, 10 cm, 12 cm, and 16 cm. These distances represented the distance of the syringe's needle tip to the collecting plate. The purpose of changing the distance was to see the effect on the fiber's diameter, abundance, and pattern that formed. In Figure 3 (to the left), the final apparatus can be seen. The syringe contains the PEO solution and the needle slowly releases the solution at a rate of 1 mL/hr. The red wire is the voltage that hits the solution and begins the fiber forming process. The silver square sheet is actually aluminum foil that is wrapped around a brown metallic sheet. This will keep the charged PEO fiber to stick onto the collecting plate and it will allow for a sample to form. The other wire (on the right) keeps the collecting plate charged for this exact reason. In the back, the holder allows the plate to be held at a certain elevation. The holder is wrapped so no current is able to pass through it.
Evan and Tristan used the solution they made the day before. The solution was 5% PEO in water and the figure on the right shows the color of the solution as well as the solution itself. The solution was clear and is perfectly mixed because it was placed in the rotational mixer. This solution was then put into the syringe to be hit by high voltage as mentioned above.
![]() |
| Figure 3. Our Electrospinning Apparatus |
![]() |
| Figure 4. 5% PEO solution used during spinning process |
Monday, April 16, 2012
Week 3 - Beginning to Spin
| Figure 1: Ethylene oxide with aid of catalyst becomes PEO [1] |
Evan and Tristan will be spinning PEO fibers at six different angles in addition to six different distances. Each fiber will be spun for 30 min and stored for SEM imaging later in the week or durring week 4. Through extensive research increasing the will make the diameter smaller and increasing the distance should also make the diameter smaller. The ideal situation in our experiment is to get the thinest PEO fibers possible with some textile strength to make a proper filter. The textile strength only has to be strong enough to handle strong water flow and if time permits these fibers will be tested for their strength after SEM imaging with a tention meter.
Subscribe to:
Posts (Atom)






